Areas of application:

Repairs to existing pipelines and new installations of pipes for the fluids water, gas accordingly to DVGW G260, compressed air, heating oil (conforming to DIN 51603-1).

Compression fittings of cast malleable iron for steel pipe:
Threaded pipes conforming to DIN EN 10255 and DIN EN 10220 Series 1.

Typical Areas of application: Domestic connection lines in the gas and drinking water supply, Fire extinguisher pipes, Piping for compressed air, Heating oil pipes, cooling agents (partly)

Fluids:

Water, Gas (outside buildings), Compressed air, Heating oil up to 2″ (follow TRBF !)

Temperatures:

Water: up to 25 °C; Heating water: up to 80 °C; Gas: –20 to +60 °C; Oil: 40 °C

Type A

with male thread

Series 150 17.2 – 60.3 mm:

Pressure stages:

Water PN 10 (up to 3/4″) respectively PN 16 (from 1″), Gas PN 5, Compressed air PN 12.5, Oil PN 6, VdS PN 12.5

Tests:

Water: DVGW W534, DVGW-Reg.-Nr.: DW-8511AU2216; Gas: DIN 3387-1, DVGW-Reg.-Nr.: NG-4502AP1454; VdS-tested from DN 25 (Fire extinguisher lines); Heating oil: Building approval DIBT, App.-No.: Z-38.4-212

Type AF

with male thread

Series 220 76.1 – 114.3 mm:

Pressure stages:
Water PN 16, Gas PN 5, Compressed air PN 10, VdS PN 16
Tests:
Water: DVGW W534, DVGW-Reg.-No.: DW-8511AU2217; Gas: DIN 3387-1, DVGW-Reg.-No.: NG-4502AP1491; VdS-tested (Fire extinguisher lines)

Type A/AF is available in the following diameters:

Type I

with female thread

Series 150 17.2 – 60.3 mm:

Pressure stages:

Water PN 10 (up to 3/4″) respectively PN 16 (from 1″), Gas PN 5, Compressed air PN 12.5, Oil PN 6, VdS PN 12.5

Tests:

Water: DVGW W534, DVGW-Reg.-Nr.: DW-8511AU2216; Gas: DIN 3387-1, DVGW-Reg.-Nr.: NG-4502AP1454; VdS-tested from DN 25 (Fire extinguisher lines); Heating oil: Building approval DIBT, App.-No.: Z-38.4-212

Type IF

with female thread

Series 220 76.1 – 114.3 mm:

Pressure stages:
Water PN 16, Gas PN 5, Compressed air PN 10, VdS PN 16
Tests:
Water: DVGW W534, DVGW-Reg.-No.: DW-8511AU2217; Gas: DIN 3387-1, DVGW-Reg.-No.: NG-4502AP1491; VdS-tested (Fire extinguisher lines)

Type I/IF is available in the following diameters:

Type O

clamping on both sides

Series 150 17.2 – 60.3 mm:

Pressure stages:

Water PN 10 (up to 3/4″) respectively PN 16 (from 1″), Gas PN 5, Compressed air PN 12.5, Oil PN 6, VdS PN 12.5

Tests:

Water: DVGW W534, DVGW-Reg.-Nr.: DW-8511AU2216; Gas: DIN 3387-1, DVGW-Reg.-Nr.: NG-4502AP1454; VdS-tested from DN 25 (Fire extinguisher lines); Heating oil: Building approval DIBT, App.-No.: Z-38.4-212

Type OF

clamping on both sides

Series 220 76.1 – 114.3 mm:

Pressure stages:
Water PN 16, Gas PN 5, Compressed air PN 10, VdS PN 16
Tests:
Water: DVGW W534, DVGW-Reg.-No.: DW-8511AU2217; Gas: DIN 3387-1, DVGW-Reg.-No.: NG-4502AP1491; VdS-tested (Fire extinguisher lines)

Type O/OF is available in the following diameters:

Type T

clamping on both sides with female outlet

Series 150 17.2 – 60.3 mm:

Pressure stages:

Water PN 10 (up to 3/4″) respectively PN 16 (from 1″), Gas PN 5, Compressed air PN 12.5, Oil PN 6

Tests:

Water: DVGW W534, DVGW-Reg.-Nr.: DW-8511AU2216; Gas: DIN 3387-1, DVGW-Reg.-Nr.: NG-4502AP1454; Heating oil: Building approval DIBT, App.-No.: Z-38.4-212

Type TF

clamping on both sides with female outlet

Series 220 76.1 – 114.3 mm:

Pressure stages:
Water PN 16, Gas PN 5, Compressed air PN 10
Tests:
Water: DVGW W534, DVGW-Reg.-No.: DW-8511AU2217; Gas: DIN 3387-1, DVGW-Reg.-No.: NG-4502AP1491

Type T/TF is available in the following diameters:

Type OR

clamping on both sides, reduced

Series 150 33.7 – 60.3 mm:

Pressure stages:

Water PN 10 (up to 3/4″) respectively PN 16 (from 1″), Gas PN 5, Compressed air PN 12.5, Oil PN 6, VdS PN 12.5

Tests:

Water: DVGW W534, DVGW-Reg.-Nr.: DW-8511AU2216; Gas: DIN 3387-1, DVGW-Reg.-Nr.: NG-4502AP1454; VdS-tested from DN 25 (Fire extinguisher lines); Heating oil: Building approval DIBT, App.-No.: Z-38.4-212

Type OR is available in the following diameters:

Type OL

clamping on both sides, long version

Series 150 21.3 – 60.3 mm:

Pressure stages:

Water PN 10 (up to 3/4″) respectively PN 16 (from 1″), Gas PN 5, Compressed air PN 12.5, Oil PN 6, VdS PN 12.5

Tests:

Water: DVGW W534, DVGW-Reg.-Nr.: DW-8511AU2216; Gas: DIN 3387-1, DVGW-Reg.-Nr.: NG-4502AP1454; VdS-tested from DN 25 (Fire extinguisher lines); Heating oil: Building approval DIBT, App.-No.: Z-38.4-212

Type OL is available in the following diameters:

Type WO

elbow, clamping on both sides

Series 150 21.3 – 60.3 mm:

Pressure stages:

Water PN 10 (up to 3/4″) respectively PN 16 (from 1″), Gas PN 5, Compressed air PN 12.5, Oil PN 6

Tests:

Water: DVGW W534, DVGW-Reg.-Nr.: DW-8511AU2216; Gas: DIN 3387-1, DVGW-Reg.-Nr.: NG-4502AP1454; Heating oil: Building approval DIBT, App.-No.: Z-38.4-212

Type WO is available in the following diameters:

Type WA

elbow, with male thread

Series 150 33.7 – 60.3 mm:

Pressure stages:

Water PN 10 (up to 3/4″) respectively PN 16 (from 1″), Gas PN 5, Compressed air PN 12.5, Oil PN 6

Tests:

Water: DVGW W534, DVGW-Reg.-Nr.: DW-8511AU2216; Gas: DIN 3387-1, DVGW-Reg.-Nr.: NG-4502AP1454; Heating oil: Building approval DIBT, App.-No.: Z-38.4-212

Type WA is available in the following diameters:

Type EK

end cap

Series 150 21.3 – 60.3 mm:

Pressure stages:

Water PN 10 (up to 3/4″) respectively PN 16 (from 1″), Gas PN 5, Compressed air PN 12.5, Oil PN 6, VdS PN 12.5

Tests:

Water: DVGW W534, DVGW-Reg.-Nr.: DW-8511AU2216; Gas: DIN 3387-1, DVGW-Reg.-Nr.: NG-4502AP1454; VdS-tested from DN 25 (Fire extinguisher lines); Heating oil: Building approval DIBT, App.-No.: Z-38.4-212

Type EKF

end cap

Series 220 76.1 mm:

Pressure stages:
Water PN 16, Gas PN 5, Compressed air PN 10, VdS PN 16
Tests:
Water: DVGW W534, DVGW-Reg.-No.: DW-8511AU2217; Gas: DIN 3387-1, DVGW-Reg.-No.: NG-4502AP1491; VdS-tested (Fire extinguisher lines)

Type EK/EKF is available in the following diameters: